Self Contained Breathing Apparatuses provide the user with breathable air regardless of the ambient atmosphere。They give respiratory protection in toxic or oxygen deficient environments..
Comply with the standard of GA124-2004
Main Features:
- New full mask with large unobstructed lens, wield vision field, impact-resistance, anti-fog and high wearing and breathing comfort combined with safety and reliability in use.
- Small and reliable Lung Demand Valve (LDV) with all the air that every one would use.
- Carbon Fiber Composite backplate with light weight and high strength. Ergonomiclly designed and comfortable to use.
- New high performance first stage pressure reducer with small and impact body incorporates a safety pressure relief valve that needs neither adjustments nor maintenances. There is a standby port reserved for the connections of external air source or other escape saving connectors.
- Water and vibrate resistant pressure gauge with back light function. Small low air whistle with light weight generates loud audio alarm.
- Cylinder valve has a secure, proven, cam-lock mechanism for reliability. Optional pressure indicating cylinder valve is available, which can indicate the cylinder pressure even the cylinder valve has been shut-off.
- 6.8L carbon cylinder can be freely interchanged with 9.0L carbon cylinder in the same backplate.
Main Speciation:

|
RHZKF9.0/30
(H2001-9.0) |
RHZKF6.8/30
(H2001-6.8) |
RHZKF4.7/30
(H2001-4.7) |
RHZKF6.8×2/30
(H2001-6.8×2) |
Total Weight |
≤12kg |
≤10kg |
≤8.5kg |
≤17kg |
Dimensions |
650×270×225 |
600×270×210 |
600×270×200 |
600×350×210 |
Operating Temperature |
-30℃~+60℃ |
Working Pressure |
30MPa |
Water Volume |
9.0L |
6.8L |
4.7L |
6.8L×2 |
Cylinder Air Capacity |
2700L |
2040L |
1410L |
4080L |
Air Supply Type |
Positive Pressure |
Max Inhalation Breathing Resistance |
≤500Pa |
Max Exhalation Breathing Resistance |
≤1000Pa |
Low Air Alarm |
5-6MPa |
Alarm Volume |
≥90dB |
CO2 in Inhalation
Breathing |
≤1% |
|